摘要
随着电能质量在线监测系统深化应用,输变电停电事件自动集成已成为电能质量在线监测系统核心的管理功能,实现了从源头系统采集数据并能自动生成停电事件。但是,停电事件生成后,还需要人工进行判断和修改停电性质及原因,增加了管理人员工作负担,同时也不能保证对相关事件管理和统计的及时性。该论文从技术路线与架构、数据流向和数据研判等方面介绍了一种基于工作票的输变电停电原因自动集成典型设计,在现有电能质量在线监测系统中实现了停电原因自动集成。
With power quality monitoring system deepening application, transmission power outage automatically integrated has become the core of the system management functions, which collects data from the source system and can automatically generate a power outage. However, these manually judgment and modification the nature and reasons for power outages are need after power outage generating, which increases management burden and can not guarantee that the relevant incident management and timeliness of statistics. This paper presents a typical design for transmission power outage automatic integration based on working- ticket, including technological route, data flow, data judging and so on, which realized the causes of power failures automatically integrated in an existing power quality monitoring system.
出处
《电测与仪表》
北大核心
2016年第S1期115-118,共4页
Electrical Measurement & Instrumentation
关键词
电能质量在线监测系统
停电原因
数据完整性
典型设计
自动集成
power quality monitoring system
the causes of power failures
data integrity
typical design
automatically in tegrated