摘要
介绍了全国辐射环境监测网络放射性气溶胶中γ核素测量考核情况及其结果分析。采用稳健统计方法处理测量结果表明,87.8%的测量值为满意结果,6.1%的测量值为有问题结果,6.1%的测量值为离群。通过比较测量结果的中位值与参考值,发现各核素测量值可能存在负的系统误差。利用此次考核,基本了解了全国辐射环境监测网络气溶胶中γ核素测量水平,为进一步做好网络质保工作提供了依据。
The results for gamma nuclides in aerosol in State Environmental Radiation Monitoring Network Measurement Assessment Program in 2013 ,held by the Environmental Radiation Monitoring Station of Zhejiang Province ,were presented .With robust statistical method employed ,it showed that 87 .8% of measurement re-sults were satisfied ,6 .1% were dubitable ,and remaining 6 .1% dissatisfied .Comparison of the resulted me-dian and the reference values indicated there may be a negative system error for the measurements of every nu-clide .With this program ,the measurement capability of gamma nuclides in aerosol in the network was general-ly understood ,which provided a basis for the future quality assurance in the respect .
出处
《辐射防护通讯》
2014年第6期32-36,共5页
Radiation Protection Bulletin
关键词
辐射环境监测
放射性气溶胶
γ核素
Radiation environmental monitoring
Aerosol