期刊文献+

Corrective Change of Retinal Thickness Measured by Optical Coherence Tomography and Histologic Studies 被引量:3

Corrective Change of Retinal Thickness Measured by Optical Coherence Tomography and Histologic Studies
下载PDF
导出
摘要 Purpose:To evaluate the correlation of retinal thickness between optical coherence tomography(OCT)images and histologic slides.Methods:Retinal thickness was measured in 16 rabbit retinal histologic slides.The same eyes has been previously measured by OCT fr the comparison of results between two methods.Retinal thickness of each OCT image section was measured using both the manually assisted(requiring localization of reflectivity peaks by observer)and automated modes of the computer software.Results:Retinal thickness measured by OCT demonstrated a high degree of correlation with retinal histologic study.The automated method(Cc=0.66,P<0.01) was less reliable than the manually assisted one (Cc=0.84,P<0.001).The former had an error in 95% confidence interval,ranged between-0.71 and 11.09μm.The latter had a less error,ranged from -2.99 to 5.13μm.Conclusion:OCT can quantitatively measure the retinal thickness.However,automatical identification of the reflective boundaries by computer may result in errors in some cases.To masure the retinal thickess by manually assisted mode can increase the accuracy. Purpose: To evaluate the correlation of retinal thickness between optical coherence tomography (OCT) images and histologic slides. Methods: Retinal thickness was measured in 16 rabbit retinal histologic slides. The same eyes had been previously measured by OCT for the comparison of results between two methods. Retinal thickness of each OCT image section was measured using both the manually assisted (requiring localization of reflectivity peaks by observer) and automated modes of the computer software. Results: Retinal thickness measured by OCT demonstrated a high degree of correlation with retinal histologic study. The automated method (Cc =0. 66, P <0. 01) was less reliable than the manually assisted one (Cc =0. 84, P <0. 001). The former had an error in 95% confidence interval, ranged between -0.71 and 11.09μm. The latter had a less error, ranged from - 2. 99 to 5. 13μm. Conclusion: OCT can quantitatively measure the retinal thickness. However, automatical identification of the reflective boundaries by computer may result in errors in some cases. To measure the retinal thickness by manually assisted mode can increase the accuracy. Eye Science 1999; 15: 153 - 155.
作者 GeJ LuoRJ
出处 《眼科学报》 1999年第3期153-153,共1页 Eye Science
关键词 光内聚 CT 视网膜厚度 组织学 optical coherence tomography(OCT), histologic, correlation, retinal thickness
  • 相关文献

同被引文献5

引证文献3

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部