摘要 大型水内冷水轮发电机绝缘参数测量经常会遇到各种各样的问题。本文分析了水内冷水轮发电机纯水引水钢管对定子机座绝缘不良会造成定子绕组绝缘参数测量严重失真的原因,提出了将引水钢管与汇水环管短接以便降低引水钢管绝缘要求的改进方案。经试验验证和三峡电站的实践,说明此方案合理、有效、可靠、方便,具有推广价值。 Large internal water cooled generator often faces various problems. This paper analyzes the reason of the measurement distortion in the stator winding insulation which caused by bad insulation between water cooled generator stator's water diversion pipe and stator frame. And the scheme of connecting the diversion steel pipe and catchment ring pipe to reduce insulation requirement of the diversion steel pipe has been proposed. By test and practice of the Three Gorges Power Station, we have proved that this scheme is reasonable, efficient, reliable, convenient, and worth to spread.
作者 杨树锋
出处 《大电机技术》 北大核心 2014年第3期53-56,共4页 Large Electric Machine and Hydraulic Turbine
关键词 水内冷 水轮发电机 定子绕组 引水钢管 绝缘 测量 失真 internal water cooling hydro-generator the stator winding steel pipe insulation measurement distortion