期刊文献+

浅析可燃性冷媒空调的安全要求 被引量:1

Analysis on New Safety Requirements for Air Conditioner With Flammable Ignition Source
下载PDF
导出
摘要 目前空调行业有计划地进行逐步淘汰HCFCs制冷剂,取而代之的是具有可燃可爆特性的环保制冷剂。空调属于用电设备,含有大量的带电部件,容易点燃可燃性气体。本文结合空调安全标准,浅析可燃制冷剂空调点火源的防护要求,供相关人员参考。 The refrigerant of HCFCs will be phase-out and replaced gradually by environmental refrigerant which are flammable and explosible. At the same time, air conditioner are electrical equipment which contains a lot of live parts, it is easy to ignite flammable gases. This paper analyzes the protection of ignition source of the air conditioner with flammable refrigerant according to the standard. It provides the reference for related personnel.
出处 《日用电器》 2015年第7期133-135,共3页 ELECTRICAL APPLIANCES
关键词 可燃制冷剂 空调 点火源 防爆 模拟泄漏实验 flammable refrigerant air conditioner ignition source electric box leak simulation test
  • 相关文献

参考文献4

  • 1Household and similar electrical appliances-Safety-Part 2-40;Particular requirements for electrical heat pumps,air-conditioners and dehumidifiers. IEC 60335-2-40 . 2005
  • 2Household and similar electrical appliances-safety-part2:Particular requirements for electrical heat pump,air conditioners and dehumidifi ers. EN 60335-2-40:2006 .
  • 3American Society of Heating Refrigerating and AirConditioning Engineers,Inc.Safety Standard for Refrigeration Systems. ANSI/ASHRAE 15/34-2010 .
  • 4ISO 817 .