摘要
本文对TELSEIS R_TD_T采集站双道不正常的故障作了较为详细的测试分析,并给出了正确的维修方法。
Our company used TELSEIS RTDT system for eight years since 1998. Because of the electronic component’s aging, some unexpected problems appeared in operation. The author of this paper accumulat-ed much experiments in the operating repairs to resolve those problems. In this paper, the author analyses the cause of double-channel STB in detail and gave the correcting method for repairing.
出处
《物探装备》
1999年第1X期43-44,53,共3页
Equipment for Geophysical Prospecting