摘要 直流电弧的静态电压电流特性是研究触点最小燃弧电压、最小燃弧电流、燃弧时间和触点开距的重要依据。本文首先阐述了电弧稳定燃烧点的确定方法,并分析了负载电阻、电动势及电感元件等因素对电弧电压电流特性及稳定燃烧点的影响,为全面掌握开关电器熄弧原理与熄弧条件奠定了基础。 The voltage-current characteristics of the stationary DC arc could be used for determination of the minimum arc voltage,the minimum arc current,arc durations and contact gap.In this paper,the method for determination of the stable arcing point is presented,and the effect of contact resistance,electric potential and the inductance on the V-I characteristics and the stable point are analyzed.It is the valuable in understanding the arc quenching theory and conditions for electric apparatus.
出处 《电气电子教学学报》 2010年第S1期41-43,共3页 Journal of Electrical and Electronic Education
基金 哈尔滨市科技创新人才研究专项资金项目(2008RFQXG043) 哈尔滨工业大学优秀青年教师培养计划资助HITQNJS.2009.024
关键词 直流电弧 稳定燃烧点 静态电压电流特性 熄弧 DC arc stable arcing point stationary voltage-current characteristics arc quenching
  • 相关文献

参考文献6

  • 1吴细秀,狄美华,李震彪,刘成衍,刘天刚.电触头侵蚀研究概述[J].低压电器,2003(5):6-11. 被引量:22
  • 2荣命哲,贾文慧,王瑞军.低压电器电极间发生的电弧放电及其特性[J].低压电器,1998(3):9-14. 被引量:12
  • 3Junya Sekikawa,,Takayoshi Kubono.An experi mental equa-tion of V-I characteristics of breaking arc for Ag,Au,Cu andNi electrical contacts[].IEICE Transactions on Electronics.
  • 4Noboru Wakatsuki,Hiroshi Honnma.Melting phenomena andarc ignition of breaking relay contacts[].Proceedings of the thIEEE Hol mconference on electrical contacts.2008
  • 5R.Hol m.Electric contacts Handbook[]..1958
  • 6R.Hol m.Electric contacts theory and applications[]..1967