期刊文献+

同相供电对再生制动引起负序电能质量问题的治理研究

Researches of Control of Negative Sequence Energy Quality Problems caused by Regenerative Braking under Co-phase Power Supply
下载PDF
导出
摘要 本文对同相供电系统列车再生制动所引起的负序电能质量问题采用满意补偿和完全补偿2种方式进行仿真分析。仿真结果表明,同相供电系统能够对列车再生制动引起的负序电能质量问题进行不同程度的治理,且同相补偿装置容量越大,负序治理效果越好。 The paper analyzes the simulations by taking two modes of satisfactory compensation and full compensation for negative sequence energy quality problems caused by regenerative braking of trains under co-phase power supply mode,the simulation results show that the co-phase power supply system is able to control the negative energy quality problems caused by regenerative braking of trains in different degrees,and the larger the capacity of co-phase compensation device is,the better of the control of negative sequence energy quality.
作者 盛望群 SHENG Wangqun
出处 《电气化铁道》 2018年第S1期104-107,共4页 Electric Railway
关键词 同相供电 再生制动 电能质量 补偿 Co-phase power supply regenerative braking energy quality compensation
  • 相关文献

参考文献10

二级参考文献80

共引文献442

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部