摘要 对底部框架 -抗震墙房屋框架所承担的地震剪力计算方法进行了讨论。指出当底部只有一层框架 -抗震墙以及底部有两层框架 -抗震墙 ,但其抗震墙高宽比h b≤ 1时 ,框架承担的地震剪力可按各抗侧力构件的侧向刚度比例分配。而对于抗震墙 1<h b≤ 4的情形 ,框架所分配的剪力如仍按各抗侧力构件的侧向刚度比例分配 。 The calculation for seismic shearing action of the bottom frame\|anti\|seismic wall house framework is discussed.It was pointed out that while there only one story of frames in the bottom\|anti\|seismic wall,or two stories of frames in the bottom\|anti\|seismic wall,but the ratio of height to width of the anti\|seismic wall is not more than 1.0( h/b≤1 ),the seismic shearing force borne by frame shall be distributed by the proportion of the lateral rigidity of te anti\|sideforce components.For the anti\|seismic wall (1 <h<b ≤4),it shall result in a major error if the shearing force still be distributed by the ratio of the lateral rigidity of the antisideforce components.
出处 《工业建筑》 CSCD 北大核心 2002年第9期32-33,共2页 Industrial Construction
关键词 框架 抗震墙 房屋 地震剪力 计算 frame\|anti\|seismic wall house\ frame shearing force