冬季“三北”地区集中供热系统中热水锅炉 (房 )大多数是低负荷运行 .根据对天津市华苑供热站运行情况进行的分析表明 ,应尽可能地提高负荷 ,对供热系统采用可行的技术措施 ,加强管理 。
In winter,most hot water boilers in central heating system in the Northwest,the Northeast,and North China are always in low load working condition.Through analysising the working condition of Huayuan heating system in Tianjin,it is indicated that increasing the load as high as possible and adopting feasible technique and administrative measure can save energy and cut down the consumption.