摘要 介绍了低频数字相位计的测量原理和校准方法,给出了低频数字相位计相位测量结果的不确定度评定的详细过程,对于低频数字相位计的校准具有很好的指导意义;同时文中的不确定度评定方法可应用于计量校准的其他类似评定中。 The measuring principle and calibration method of low frequency digital phase meter are introduced, and the detailed process of uncertainty evaluation of phase measurement results of low frequency digital phase meter is given, which has a good guiding significance for the calibration of low frequency phase meter, and the proposed uncertainty evaluation method can be applied to other similar evaluation of calibration.
作者 申祥平 陈彦 杨桥新 SHEN Xiangping;CHEN Yan;YANG Qiaoxin(CEPREI,Guangzhou 510610,China)
出处 《电子产品可靠性与环境试验》 2018年第A01期147-149,共3页 Electronic Product Reliability and Environmental Testing
关键词 低频数字相位计 测量原理 校准方法 测量不确定度 low frequency digital phase meter measuring principle calibration method measurement uncertainty