摘要
给出了分别按GBJ10 -89规范及混合耗能机制设计预应力混凝土框架在低周反复荷载下的试验结果 ,并对试验结果进行了对比分析 ,指出了混合耗能机制的预应力混凝土框架有良好的抗震性能 。
The test results of the prestressed concrete frame structures under the reversed cyclic loading is presented,which are designed with the GBJ10-89 code and mixed energy dissipation mechanism,the test result is analysed, it's pointed out that the prestressed concrete frame structures designed with mixed energy dissipation mechanism hare enough aseismic capacity,the result of the PUSHOVER analysis fixes with the test results very well.
出处
《工业建筑》
CSCD
北大核心
2002年第10期17-19,22,共4页
Industrial Construction
关键词
预应力混凝土
框架结构
抗震能力
试验
prestressed concrete\ frame structures\ aseismic capacity test