单一用途的24h便携式食管pH值检测锑探头必须进行测试后校准

Post-test calibration of single-use,antimony,24-hour ambulatory esophageal pH probes is necessary
下载PDF
导出
摘要 Twenty-four-hour pH monitoring is considered the “ gold standard” for detection of gastroesophageal reflux disease (GERD).However, reference pH can drift during studies using antimony pH electrodes. Posttest calibration of antimony probes to assess a “ drift” has been advocated but is not routinely preformed in clinical practice. We undertook this study to determine the frequency and degree of drift that occurs during pH studies using single-use antimony pH electrodes. One hundred consecutive 24-hr ambulatory esophageal pH studies were reviewed for presence and degree of pH drift. Separately, 10 in vitro studies using antimony electrodes exposed to solution of constant pH and temperature were recorded to determine timing of drift.Drift of at least 0.1 pH unit occurred in 88 (P < 0.001). Drift of 0.1, 0.2, 0.3, 0.4, and >0.4 pH unit occurred in 38, 28, 15,4, and 5 of the 100 studies, respectively. In six studies the adjustment for the poststudy calibration drift changed the overall interpretation of the test. Small degrees of drift occurred atvarious times during the 10 in vitro studies. Drift in pH during 24-hr pH studies using antimony is common, but large degrees of drift are not. When the threshold of pH 4.0 was adjusted to reflect the drift, a small but significant number of interpretations changed. Drift artifact may impact the results of the pH study,and calibration should be repeated after all studies. Twenty-four-hour pH monitoring is considered the “ gold standard” for detection of gastroesophageal reflux disease (GERD).However, reference pH can drift during studies using antimony pH electrodes. Posttest calibration of antimony probes to assess a “ drift” has been advocated but is not routinely preformed in clinical practice. We undertook this study to determine the frequency and degree of drift that occurs during pH studies using single-use antimony pH electrodes. One hundred consecutive 24-hr ambulatory esophageal pH studies were reviewed for presence and degree of pH drift. Separately, 10 in vitro studies using antimony electrodes exposed to solution of constant pH and temperature were recorded to determine timing of drift.Drift of at least 0.1 pH unit occurred in 88 (P < 0.001). Drift of 0.1, 0.2, 0.3, 0.4, and >0.4 pH unit occurred in 38, 28, 15,4, and 5 of the 100 studies, respectively. In six studies the adjustment for the poststudy calibration drift changed the overall interpretation of the test. Small degrees of drift occurred atvarious times during the 10 in vitro studies. Drift in pH during 24-hr pH studies using antimony is common, but large degrees of drift are not. When the threshold of pH 4.0 was adjusted to reflect the drift, a small but significant number of interpretations changed. Drift artifact may impact the results of the pH study,and calibration should be repeated after all studies.
出处 《世界核心医学期刊文摘(胃肠病学分册)》 2005年第1期11-12,共2页 Core Journals in Gastroenterology
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部