比较四槽法(含酶洗涤剂)与三槽法清洗消毒对细菌学监测的影响。采用四槽分步法彻底清洗、消毒胃镜。60支胃镜经四槽清洗、消毒后和60支胃镜经三槽清洗、消毒后对照 ,其细菌数分别为9.3±3.8与22.6±6.5(cfu/件)。含酶洗涤剂是使用戊二醛前的清洁洗涤剂 ,能提高消毒效果 ,经统计学处理 ,P<0.05。
We investigated the results of bacteriological surveillance after four steps and three steps disinfection.for gastroscope that the basteria were 9.3±3.8and 22.6±6.5(cfu/piece)respectively. The four steps method,enzyme compound disinfectant was used as the disinfectants before using Glutaraldehyde, can improve the effect of disinfection(p<0.05).
出处
《医疗设备信息》
2002年第9期40-41,43,共3页
Information of Medical Equipment
关键词
胃镜
消毒
化学方法
细菌学监测
gastroscope
disinfection
chemical method