期刊文献+

烷基汞环境标准样品的研制 被引量:1

DEVELOPMENT OF ALKYL MERCURY ENVIRONMENTAL REFERENCE MATERIALS
下载PDF
导出
摘要 依据《标准样品工作导则》(GB/T 15000-94)技术要求,以苯作为溶剂,采用重量法配制甲基汞和乙基汞环境标准样品。经过均匀性、稳定性检验后,由8家实验室用气相色谱法和冷原子吸收分光光度法协作定值,经数理统计检验,给出了这两种标准样品的标准值和不确定度。 Methyl mercury and ethyl mercury environmental reference materials (ERMs) were developed using gravimetric method with benzene as solvent according to GB/T 15000-94. After the homogeneity and stability being tested, the ERMs certificated value and uncertainty were given after mathematical statistics of all data from eight labs using gas chromatography and cold vapour atomic absorption methods.
出处 《化学分析计量》 CAS 2002年第5期4-6,共3页 Chemical Analysis And Meterage
关键词 烷基汞 甲基汞 乙基汞 环境标准样品 环境监测 污染物 methyl mercury, ethyl mercury, environemtal reference material, developing
  • 相关文献

参考文献3

二级参考文献2

  • 1全浩.标准物质及其应用技术[M]中国标准出版社,1990.
  • 2中国环境优先监测研究课题组.环境优先污染物[M]中国环境科学出版社,1989.

共引文献26

同被引文献18

  • 1Harris H H, Pickering I J, George G N. The chemical form of mercu ry in fish. Science, 2003 ; 301 : 1203.
  • 2Gao Y, Shi Z M, Long Z, et al. Determination and speciation of mer- cury in environmental and biological samples by analytical atomic spectrometry. Microchemical Journal, 2012; 103:1-14.
  • 3Mao Y X, Liu G L, Meichel G, et al. Simultaneous speciation of monemethylmercury and monoethylmercury by aqueous phenylation and purge-and-trap preconcentration followed by atomic spectrometry detection. Analytical Chemistry, 2008 ; 80 : 7163-7168.
  • 4Westoo G. Determination of methylmercury compounds in foodstuffs I. methylmercury Compounds in fish, Idification and Determination. Chem Scand, 1966 ;20(8) :2131-2137.
  • 5Bloom N. Determination of picogram levels of methylmercury by aque- ous phase ethylation, followed by cryogenic gas chromatography with cold vapour atomic fluorescence detection. Canadian Journal of Fish- eries and Aquatic Sciences, 1989 ;46 (7) : 1131-1140.
  • 6Lee Y H, Mowrer J. Determination of methylmercury in natural wa- ters at the sub-nanograms per litre level by capillary gas chromatogra- phy after adsorbent preconcentration. Mowrer-Analytica Chimica Ac- ta, 1989 ;221(2) :259-268.
  • 7Beauchemin P, Siu K W M, Berman S S. Determination of organo- mercury in biological reference materials by inductively coupled plas- ma mass spectrometry using flow injection analysis . Anal Chem. 1988 ;60 ( 23 ) :2587-2590.
  • 8Emteborg H, Sinemus H W, Radziuk B, et al. Gas chromatography coupled with atomic absorption spectrometry-a sensitive instrumenta- tion for mercury speciation. Spectrochim Acta B, 1996;51 (8) :829-837.
  • 9Cela R, Lorenzo R A, Rubi E, et al. Mercury speciation in raw sediments of the pontevedra estuary (Galicia-Spain). Environ Tech- nol, 1992;13(1) :11-22.
  • 10Horvat M, Liang Lian, Bloom N S. Comparison of distillation with other current isolation methods for the determination of methyl mer- cury compounds in low level environmental samples : Part II. Water. Analytica Chimica Acta. 1993 ;282 ( 1 ) : 153-168.

引证文献1