摘要
本文作者通过分析DG670 / 14 0 -8型锅炉再热气温偏低的原因 ,提出改造方案。经改造后 ,锅炉再热汽温达到了要求并提高了锅炉运行的安全性和经济性。
This paper analyzes the reasons of the temperature deviation of reheated steam on the low side in DG670/140-8 boiler in Chengdu heat power plant.Measures for improving the temperature deviation are proposed.After reconstruction,the temperature of reheated steam meets the requirements and the safety and economical effect of boiler operation are improved.
出处
《四川工业学院学报》
2002年第3期53-54,共2页
Journal of Sichuan University of Science and Technology
关键词
锅炉
再热汽温偏低
运行
再热器
原因分析
技术改造
boiler
the temperature of reheated steam deviating on the low side
reason
reconstruction