摘要
介绍了国产化离子膜电解整流设备在新疆天业股份有限公司石河子中发化工有限责任公司4万t/a离子膜烧碱技改工程中的运行情况,并阐述了该装置在运行中出现的问题及解决方法。
The running conditions of domestic rectifier for ion-exchange membrane electrolyzer during the technological modification of 40 kt/a ion-exchange membrane caustic soda production facility in Shihezi Zhongfa Chemical Co.,Ltd.of Xinjiang Tianye Inc.was introduced.Problems existing in the running of this device and methods to solve them were also introduced.
出处
《氯碱工业》
CAS
2002年第10期9-11,共3页
Chlor-Alkali Industry
关键词
烧碱
离子膜
复极槽
整流装置
运行
保护
ion-exchange membrane
bipolar electrolyzer
rectifier
running
protection