摘要 本文追述了十年前一起支柱垂直度严重超差的1000m3 液化石油气球罐的检验和缺陷分析 。 In this paper,the inspection and flaw analysis carried out ten years ago for one 1000 m3 petroleum gas spherical tank in which the vertical degree for the prop was seriously violated were stated.Then,the repair method was introduced,and the method was proved correct with the fact of the operation of the tank for ten years.
作者 陈鹍棠
出处 《化工设备与管道》 CAS 2002年第4期22-24,共3页 Process Equipment & Piping
关键词 垂直度超标 球罐支柱 严重倾斜 处理方案 液化石油气 缺陷 油气罐 prop of spherical tank,seriously inclined,treatment measure