期刊文献+

Full-scale tests of wind effects on a long span roof structure 被引量:5

Full-scale tests of wind effects on a long span roof structure
下载PDF
导出
摘要 Full-scale measurements are regarded as the most reliable method to evaluate wind effects on large buildings and structures. Some selected results are presented in this paper from the full-scale measurement of wind effects on a long-span steel roof structure during the passage of Typhoon Fanapi. Some fi eld data, including wind speed and direction, acceleration responses, etc., were continuously and simultaneously recorded during the passage of the typhoon. Comprehensive analysis of the measured data is conducted to evaluate the typhoon-generated wind characteristics and its effects on a long-span steel roof. The fi rst four natural frequencies and their vibration mode shapes of the Guangzhou International Sports Arena(GISA) roof are evaluated by the stochastic subspace identifi cation(SSI) method and comparisons with those from fi nite element(FE) analysis are made. Meanwhile, damping ratios of the roof are also identifi ed by the SSI method and compared with those identifi ed by the random decrement method; the amplitude-dependent damping behaviors are also discussed. The fullscale measurement results are further compared with the corresponding wind tunnel test results to evaluate its reliability. The results obtained from this study are valuable for academic and professional engineers involved in the design of large-span roof structures. Full-scale measurements are regarded as the most reliable method to evaluate wind effects on large buildings and structures. Some selected results are presented in this paper from the full-scale measurement of wind effects on a long-span steel roof structure during the passage of Typhoon Fanapi. Some fi eld data, including wind speed and direction, acceleration responses, etc., were continuously and simultaneously recorded during the passage of the typhoon. Comprehensive analysis of the measured data is conducted to evaluate the typhoon-generated wind characteristics and its effects on a long-span steel roof. The fi rst four natural frequencies and their vibration mode shapes of the Guangzhou International Sports Arena(GISA) roof are evaluated by the stochastic subspace identifi cation(SSI) method and comparisons with those from fi nite element(FE) analysis are made. Meanwhile, damping ratios of the roof are also identifi ed by the SSI method and compared with those identifi ed by the random decrement method; the amplitude-dependent damping behaviors are also discussed. The fullscale measurement results are further compared with the corresponding wind tunnel test results to evaluate its reliability. The results obtained from this study are valuable for academic and professional engineers involved in the design of large-span roof structures.
出处 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2015年第2期361-372,共12页 地震工程与工程振动(英文刊)
基金 National Natural Science Foundation of China under Grant Nos.51222801 and 51378134 Yangcheng Scholarship in Guangzhou Municipal Universities under Project No.12A004S the Research Funding for Ph.D Programme in Higher Education Universities under Project No.20124410110005
关键词 long-span steel roof wind effect field measurement long-span steel roof wind effect field measurement
  • 相关文献

参考文献20

  • 1Han Jianping,Zheng Peijuan,Wang Hongtao.Structural modal parameter identifi cation and damage diagnosis based on Hilbert-Huang transform[J].Earthquake Engineering and Engineering Vibration,2014,13(1):101-111. 被引量:14
  • 2Shuenn-Yih Chang.Nonlinear performance of classical damping[J].Earthquake Engineering and Engineering Vibration,2013,12(2):279-296. 被引量:1
  • 3Wang Jinting,Lü Dandan,Jin Feng,Zhang Chuhan.Accuracy of the half-power bandwidth method with a third-order correction for estimating damping in multi-DOF systems[J].Earthquake Engineering and Engineering Vibration,2013,12(1):33-38. 被引量:3
  • 4Virote Boonyapinyo,Tharach Janesupasaeree.Data-driven stochastic subspace identification of flutter derivatives of bridge decks[J]. Journal of Wind Engineering & Industrial Aerodynamics . 2010 (12)
  • 5Q.S. Li,Y.Q. Xiao,C.K. Wong.Full-scale monitoring of typhoon effects on super tall buildings[J]. Journal of Fluids and Structures . 2005 (5)
  • 6Ming Gu,Xian-Rong Qin.Direct identification of flutter derivatives and aerodynamic admittances of bridge decks[J]. Engineering Structures . 2004 (14)
  • 7Q.S. Li,Y.Q. Xiao,C.K. Wong,A.P. Jeary.Field measurements of typhoon effects on a super tall building[J]. Engineering Structures . 2003 (2)
  • 8Q. S.Li,J. Q.Fang,A. P.Jeary,C. K.Wong,D. K.Liu.Evaluation of wind effects on a supertall building based on full‐scale measurements[J]. Earthquake Engng. Struct. Dyn. . 2000 (12)
  • 9Q.S Li,D.K Liu,J.Q Fang,A.P Jeary,C.K Wong.Damping in buildings: its neural network model and AR model[J]. Engineering Structures . 2000 (9)
  • 10G. Solari,G. Piccardo.Probabilistic 3-D turbulence modeling for gust buffeting of structures[J]. Probabilistic Engineering Mechanics . 2000 (1)

二级参考文献29

  • 1Chopra AK (2007), Dynamics of Structures." Theory and Applications to Earthquake Engineering. Prentice-hall, Inc., Englewood Cliffs, N.J.
  • 2Papaginanopoulos GA and Hatzigeorgiou GD (2011), "On the Use of the Half-power Bandwidth Method to Estimate Damping in Building Structures," Soil Dynamics and Earthquake Engineering, 31: 1075 1079.
  • 3Wang I (2011), "An Analysis of Higher Order Effects in the Half Power Method for Calculating Damping," Journal of Applied Mechanics,78:014501.
  • 4Wang Jinting, Jin Feng and Zhang Chuhan (2012), "Estimation Error of the Half-power Bandwidth Method in Identifying Damping for Multi-DOF Systems," Soil Dynamics and Earthquake Engineering, 39:138-142.
  • 5Adhikari S and Woodhouse J (2003), "Quantification of Non-viscous Damping in Discrete Linear Systems," Journal of Sound and Vibration, 260:499-518.
  • 6Bathe KJ and Wilson EL (1973), "Stability and Accuracy Analysis of Direct Integration Methods," Earthquake Engineering and Structural Dynamics, 1: 283-291.
  • 7Bernal D (1994), "Viscous Damping in Inelastic Structural Response," JournalofStructuralEngineering, 120(4): 1240-1254.
  • 8Caughey TK (1960), "Classical Normal Modes in Damped Linear Systems," Journal of Applied Mechanics, ASME, 27:269-271.
  • 9Caughey TK and O'Kelly MEJ (1965), "Classical Normal Modes in Damped Linear Systems," Journal of Applied Mechanics, ASME, 32: 583-588.
  • 10Chang SY (1997), "Improved Numerical Dissipation for Explicit Methods in Pseudodynamic Tests," Earthquake Engineering and Structural Dynamics, 26:917-929.

共引文献17