摘要 介绍了MPV 3显微光度计镜质组反射率测量和数据处理自动化系统的测控原理、具体软 /硬件实现及其系统功能、特点。系统具有标样 /样品反射率测量、反射率线性检查、误差分析与处理、反射率分阶直方图统计、数据在线更改与自动存储等功能 ;同时系统还具有自动动开启 This article introduces measurement and control principle, implementation of specific software and hardware, functions and features of MPV-3 micro-luminosity meter group reflecting rate measuring and data processing automation system. The system is possessed of such functions as sample/standard sample reflecting rate measuring, lineal check of reflecting rate, error analyzing and processing, segmentation diagram counting of reflecting rate, data modifying on-line and saving automatically. At the same time, the system can control opening and closing of macro-luminosity meter automatically.