本文介绍了应用GC-MS/MS(CI离子源)法进行尿中哌替啶及其代谢物的快速定性方法。方法的回收率迭85%以上,GC-MS/MS的最低检出限为0.05ng,方法的最低检出浓度为:10ppb。完全满足确证48小时以内是否口服或注射哌替啶的需要。
This text introduced the quick qualitative of application GC-MS/MS (CI source) in that low urine Pethidine and his metabolite. The lowest GC-MS/MS measure; 0.05ng; The lowest methodological consistency: 10ppb. Whether or not satisty to prove conclusively within 48 hours completely or injecting pethidine the needs.