摘要
介绍了CG - 75 / 5 .3-MX型循环流化床锅炉采用 (MC +EP)高效多管静电组合式除尘器的应用状况。在燃用低位发热值Qnet,ar =12 5 12kJ/kg ,灰分 Aar =35 .0 %~ 38.0 %劣质煤煤时 ,锅炉初始排尘浓度为 2 396 4 .1~ 2 5 2 6 2 .4mg/Nm3 (折算到α =1.8)时 ,(MC +EP)高效多管静电组合式除尘器出口烟尘排放浓度为 380 .0~ 318.4mg/Nm3 (折算到α =1.8) ,除尘效率达 98.71%~ 98.74 % ,除尘器阻力为 12 90Pa ,分割粒径为 1.15 μm ,林格曼黑度 1级以下。
When Q net.ar =12 512 kJ/kg, A ar =35.0%~38.0%, and the initial dust discharge concentration is 23 964.1~25 262.4 mg/Nm 3, the dust discharge concentration out from the outlet of (MC+EP) high efficiency multi tube static combination dust remover is 380.0~318.4 mg/Nm 3, the dust removal efficiency is 98.71%~98.74%, the resistance of remover is 1 290 Pa, the particle size is 1.15 μm, and the geman blackness is below class 1.
出处
《黑龙江电力》
CAS
2002年第5期346-348,共3页
Heilongjiang Electric Power