摘要 近年来,随着国家对环保要求的日益提高,各炼厂烟气脱硫、脱销项目纷纷上马。独山子石化根据Ⅰ催化装置的再生烟气量小、高含硫含氮量的特点,通过对比SCR+EDV技术、罗塔斯+EDV技术、脱硫脱硝一体化技术、WGS技术,最终选择工艺技术方案流程相对简单、适应性强、运行费用相对较低的SCR+EDV技术。装置改造后,自2014年7月起烟气中SO_X浓度、NO_X浓度能够满足奎独乌特别排放要求。 As the increasing national requirements on environmental protection,more and more projects of flue-gas desulfurization and denitrogenation are launched in many oil refinery plants in recent years.Basing on the characteristics of low volume,high sulfur content and high nitrogen content in the regeneration flue-gas of catalytic unit I,Dushanzi company compares the technologies of SCR+EDV,LoTOx+EDV,simultaneous desulfurization/denitrification and WGS,and finally chooses SCR+EDV technology because it is relatively simple,well adapted and its operational cost is relatively low.After the retrofit is completed,the concentrations of SOx and NOx in regeneration flue-gas can meet the special emission requirements in Kuytun,Usa and Dushanzi area since July,2014.
作者 刘伟 Liu Wei(Programming and Planning Department Of Petrochina Dushanzi Petrochemical Company,Karamay 833699,China)
出处 《石化技术》 CAS 2016年第2期12-13,共2页 Petrochemical Industry Technology
关键词 烟气脱硫技术炼厂催化裂化烟气 污染物 flue-gas desulphurization technology catalytic cracking flue gas pollutant