期刊文献+

MTP装置LPG样∑C5+超标原因分析

Analysis of the Reason for Exceeding LPG Sample ∑ C5+ Content in MTP Unit
下载PDF
导出
摘要 在MTP装置中,∑C5+主要是以循环烃形式回反应器控制床层温度。∑C5+含量直接影响LPG产品的汽化和目的产物收率。故LPG出装时要严格控制∑C5+含量。本文对LPG样∑C5+含量超标原因进行深入分析,结果表明,脱丁烷塔顶冷凝器换热效果直接影响∑C5+去向。 In MTP device, Σ C5 + mainly take the reactorback in cyclic hydrocarbon form to control the bed temperature. The Σ C5 + contentdirectly affect the vaporization of LPG products and target product yield coefficient,so we should strictly control the Σ C5 + content when the LPG ispacked.In this paper, it takes deep analysis of the reason for the exceeding LPG sample Σ C5 + content,and the results show that the the heat transfereffect of debutanizer condenser directly affect the performance of Σ C5 +.
作者 温润娟 许锐 刘超 Wen Runjuan;Xu Rui;Liu Chao(Coal Chemical Industry Branch of SNCG, Ningxia, 750411)
出处 《当代化工研究》 2016年第6期120-121,共2页 Modern Chemical Research
关键词 LPG样ΣC5+含量 换热效果 循环水质 LPG sampleC5+ content heat transfer effect circulating water qualityf