摘要
对二甲基乙二醛肟析出-EDTA络合滴定法测定系列钯化合物中钯量的不确定度进行了分析与评定,并计算出扩展不确定度。结果表明,测定二氯化钯、醋酸钯、二氯四氨钯、硝酸钯溶液和硫酸钯溶液中59.59%、47.73%、42.46%、17.64%和4.01%的钯含量,扩展不确定度分别为0.30%、0.26%、0.24%、0.10%和0.03%。不确定度主要来源于终点判断和标定过程。
The uncertainty for complexometric titration of EDTA to determine the palladium contents in palladium compounds was evaluated, and the expanded uncertainties were calculated. Results indicated that the expanded uncertainties are 0.30%, 0.26%, 0.24%, 0.10% and 0.03% for palladium contents of 59.59% (PdCl2), 47.73% (Pd(OAc)2), 42.46% (Pd(NH3)4Cl2), 17.64% (Pd(NO3)2 solution) and 4.01% (PdSO4 solution) in palladium compounds, respectively. The uncertainty mainly came from the end judgment and calibration process.
作者
邢银娟
甘建壮
金娅秋
曾荷峰
马媛
陶赛详
杨梅英
钱彦林
XING Yinjuan;GAN Jianzhuang;JIN Yaqiu;ZENG Hefeng;MA Yuan;TAO Saixiang;YANG Meiying;QIAN Yanlin(State Key Laboratory of Advanced Technologies for Comprehensive Utilization of Platinum Metals, Sino-Platinum Metals Co. Ltd., Kunming 650106, China)
出处
《贵金属》
CAS
CSCD
北大核心
2016年第3期60-65,共6页
Precious Metals
关键词
分析化学
不确定度
络合滴定
钯化合物
analytical chemistry
uncertainty
complexometric titration
palladium compounds