摘要
目的:探讨头颅CTA扫描时合理、精准地使用造影剂剂量。方法:收治行头颅CTA扫描患者100例,选取wills环作为观察区域,在不同造影剂剂量条件下扫描,得出三组图像,进行分析和比较。结果:头颅CTA扫描时图像符合临床诊断标准的最少造影剂剂量为40 m L。结论:头颅CTA扫描时合理、精准地使用造影剂剂量能减少造影剂对人体的危害。
Objective:To explore the reasonable and accurate dose of contrast agent in head CTA.Methods:100 patients with headCTA were selected.Wills ring was chosen as the observation region,which was scanned at different contrast agent dose,and weanalyzed the obtained three groups of images.Results:The minimum dose of contrast agent was 40 mL in head CTA,and the imageswere consistent with clinical diagnostic criteria.Conclusion:Reasonably and accurately using the contrast agent dose in head CTAcan reduce the harm to the human body.
作者
李吉平
冯佳
Li Jiping;Feng Jia(The Fourth Affiliated Hospital of Inner Mongolia Medical College 014030)
出处
《中国社区医师》
2016年第22期149-149,共1页
Chinese Community Doctors
关键词
能谱CT
头颅CTA
造影剂最少剂量
Energy spectrum CT
Head CTA
The minimum dosage of contrast agent