摘要 目的:研究支气管气囊压力观察法用于左侧双腔支气管插管定位的效果。方法:将左侧双腔支气管插管患者分为A组(气囊压力组)、B组(导管阻力组)、C组(身高预测组),比较3组患者插管情况及相关并发症例数。结果:A组患者首次插管时肺分隔成功例数、位置准确例数多于B组、C组,位置过浅、过深例数少于B组、C组。结论:支气管气囊压力观察法用于左侧双腔支气管插管的定位效果优于导管阻力法、身高预测法。 Objective:To study the effect of the application of bronchial balloon pressure observation method in left side doublelumen bronchial intubation positioning.Methods:The patients with left side double lumen bronchial intubation were divided into Agroup(the balloon pressure group),B group(the pipe resistance group),C group(the height prediction group).The intubation situationsand related complication cases of 3 groups were compared.Results:The lung separation successful cases and location accuracycases on the first intubation in A group were more than those of B group and C group;too shallow and too deep position caseswere less than those of B group and C group.Conclusion:The effect of bronchial balloon pressure observation method in left sidedouble lumen bronchial intubation positioning is better than that of pipe resistance method and height prediction method.
作者 许伯林 王庆安 李良文 Xu Bolin;Wang Qin′an;Li Liangwen(Department of Anesthesia,Santai County People's Hospital of Sichuan 621100)
出处 《中国社区医师》 2016年第19期54-54,56,共2页 Chinese Community Doctors
关键词 支气管插管 支气管气囊压力 插管定位 Bronchial intubation Bronchial balloon pressure Intubation positioning
  • 相关文献

参考文献2

二级参考文献23

  • 1吴文冬,陈建庆.纤维支气管镜在双腔支气管插管定位中的应用[J].右江民族医学院学报,2007,29(2):225-226. 被引量:3
  • 2秦丹丹,张学刚,叶凤青,黄中华,李静,胡彦艳.不同定位方法在双腔支气管导管插管中的比较[J].现代医药卫生,2007,23(10):1426-1427. 被引量:2
  • 3Brodsky JB,Macario A,Mark JB.Tracheal diameter pre-dicts double-lumen tube size:a method for selecting left double-lumen tubes[J].Anesth Analg,1996,82(4):861-864.
  • 4Brodsky JB,Benumof JL,Ehrenwerth J,et al.Depth of placement of left double-lumen endobronchial tubes [ J ].Anesth Analg,1991,73(5):570-572.
  • 5Chow MY,Goh MH,Ti LK.Predicting the depth of insertion of left-sided double-lumen endobronchial tubes [ J ].J Car-diothorac Vasc Anesth,2002,16(4):456-458.
  • 6Bahk JH,Lira YJ,Kim CS.Positioning of a double-lumen endobronchial tube without the aid of any instruments:an implication for emergency management [ J ].J Trauma,2000,49(5):899-902.
  • 7Cheong KF,Koh KF.Placement of left-sided double-lmnen en-dobronchial tubes:comparison of clinical and fibreoptic-guided placement[J].Br J Anaesth,1999,82(6):920-921.
  • 8Yasumoto M,Higa K,Nitahara K,et al.Optimal depth of insertion of left-sided double-lumen endobronchial tubes cannot be predicted from body height in below average-sized adult patients [ J ].Eur J Anaesthesiol,2006,23(1):42-44.
  • 9Bahk JH,Oh YS.A new and simple maneuver to position the left-sided double-lumen tube without the aid of fibemptic bmn-choscopy[J].Anesth Analg,1998,86(6):1 271-1 275.
  • 10Bahk JH, Lim YJ, Kim CS. Positioning of a double-lumen endobron- chial tube without the aid of any instruments:an implication for e- mergency management [ J ]. J Trauma,2000,49 (5) : 899 - 902.

共引文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部