摘要 在长期的运行跟踪过程中发现,不论是国外的还是国内的智能干式负载箱,普遍存在电阻管容易受高温损坏而影响使用寿命的问题。除了电阻管制造工艺和其本身的质量等内因之外,散热效果对电阻管的寿命起决定性作用。散热效果取决于散热风机的风量、散热通道和环境。对此,以中国船舶电站设备有限公司的智能干式负载箱为例,就如何改进设计进风通道和出风通道,提升散热风机风量,达到提高负载箱散热的效果进行深入研究。同时,对实际应用中取得较好效果的情况进行介绍,供同行参考。 It is found through long-term operation observations that the service life of the intelligent load banks has beenreduced, both at home and abroad, due to the resistance tube damage caused by high temperature. Apart from the resistancetube manufacturing technique and its own quality factors, heat dissipation performance plays a vital role in determining thelifecycle of the tube, whereas the dissipation performance depends on the blast capacity of the fan, the cooling channel andthe environment. Taking the dry-type intelligent load bank of China Ship Power Station Co., Ltd. as the example, studies arecarried out to improve the design of air inlet duct and outlet duct, to increase blast capacity of the fan, and to enhance thedissipation performance. Moreover, practical methods that can achieve better result are explained in the paper for reference.
作者 董秋苏 张宏 DONG Qiu-su;ZHANG Hong(China Ship Power Station Co., Ltd., Shanghai 200129, China)
出处 《船舶与海洋工程》 2016年第5期61-66,79,共7页 Naval Architecture and Ocean Engineering
关键词 智能干式负载箱 柴油发电机组试验设备 电阻负载 进风通道 出风通道 风机风量 散热效果 dry-type intelligent load bank diesel generator test equipment resistance load air inlet duct air outlet duct blast capacity of fan heat dissipation
  • 相关文献

参考文献3

  • 1中华人民共和国国家质量监督检验检疫总局,中国国家标准化管理委员会. 船用柴油发电机组:GB/T 13032—2010[S].北京:中国标准出版社,2010.
  • 2中华人民共和国国家发展和改革委员会. 一般用途轴流通风机技术条件:JB/T 10562—2006[S]. 北京:机械工业出版社,2006.
  • 3中华人民共和国国家质量监督检验检疫总局. 工业通风机 用标准化风道进行性能试验:GB/T 1236—2000[S]. 北京:中国标准出版社,2000.