期刊文献+

Numerical Simulation for Two-Phase Water Hammer Flows in Pipe by Quasi-Two-Dimensional Model 被引量:1

Numerical Simulation for Two-Phase Water Hammer Flows in Pipe by Quasi-Two-Dimensional Model
下载PDF
导出
摘要 The features of a quasi-two-dimensional( quasi-2D) model for simulating two-phase water hammer flows with vaporous cavity in a pipe are investigated. The quasi-2D model with discrete vaporous cavity in the pipe is proposed in this paper. This model uses the quasi-2D model for pure liquid zone and one-dimensional( 1D) discrete vapor cavity model for vaporous cavity zone. The quasi-2D model solves two-dimensional equations for both axial and radial velocities and 1D equations for both pressure head and discharge by the method of characteristics. The 1D discrete vapor cavity model is used to simulate the vaporous cavity occurred when the pressure in the local pipe is lower than the vapor pressure of the liquid. The proposed model is used to simulate two-phase water flows caused by the rapid downstream valve closure in a reservoir-pipe-valve system.The results obtained by the proposed model are compared with those by the corresponding 1D model and the experimental ones provided by the literature,respectively. The comparison shows that the maximum pressure heads simulated by the proposed model are more accurate than those by the corresponding 1D model. The features of a quasi-two-dimensional( quasi-2D) model for simulating two-phase water hammer flows with vaporous cavity in a pipe are investigated. The quasi-2D model with discrete vaporous cavity in the pipe is proposed in this paper. This model uses the quasi-2D model for pure liquid zone and one-dimensional( 1D) discrete vapor cavity model for vaporous cavity zone. The quasi-2D model solves two-dimensional equations for both axial and radial velocities and 1D equations for both pressure head and discharge by the method of characteristics. The 1D discrete vapor cavity model is used to simulate the vaporous cavity occurred when the pressure in the local pipe is lower than the vapor pressure of the liquid. The proposed model is used to simulate two-phase water flows caused by the rapid downstream valve closure in a reservoir-pipe-valve system.The results obtained by the proposed model are compared with those by the corresponding 1D model and the experimental ones provided by the literature,respectively. The comparison shows that the maximum pressure heads simulated by the proposed model are more accurate than those by the corresponding 1D model.
出处 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2016年第2期9-15,共7页 哈尔滨工业大学学报(英文版)
基金 Sponsored by the National Natural Science Foundation of China(Grant No.51208160) the Natural Science Foundation of Heilongjiang Province(Grant No.QC2012C056)
关键词 water HAMMER method of characteristics QUASI -two -dimensional MODEL COLUMN separation discrete vapor cavity MODEL water hammer method of characteristics quasi-two-dimensional model column separation discrete vapor cavity model
  • 相关文献

同被引文献1

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部