超声血流向量成像技术评价心腔内流体能量损耗的研究及进展 被引量:1

Research and development of the heart cavity by ultrasonic blood flow imaging on evaluation of the energy loss of the fluid flow
下载PDF
导出
摘要 目的:超声血流向量成像技术应用于测定血流黏滞摩擦引起的能量损耗,不仅能用于各种疾病心功能的评定,而且对肺动脉瓣狭窄、主动脉瓣狭窄及反流等心血管疾病的病情评估、预后及治疗效果等方面有着广泛的临床应用价值。本文就VFM对于心腔内流体能量损耗的研究及进展做一综述。 Ultrasonic blood flow imaging technique was applied to measure the energy loss caused by viscous friction.It can beused not only for evaluation of various diseases of heart function,but also has wide clinical application value on pulmonary valvestenosis,aortic stenosis and regurgitation of cardiovascular disease,prognosis and therapeutic effect evaluation.In this paper,wereview the research and progress of VFM on the energy loss of the fluid in the heart cavity.
作者 杨翠 丁云川 王庆慧 陈剑 尹帆 张瑜 Yang Cui;Ding Yunchuan;Wang Qinghui;Chen Jian;Yin Fan;Zhang Yu(Department of Ultrasound,Yanan Hospital Affiliated to Kunming Medical University,Kunming City of Yunnan Province 650051)
出处 《中国社区医师》 2016年第35期10-11,15,共3页 Chinese Community Doctors
基金 云南省科技厅昆医应用基础研究联合专项项目(2012FB100)~~
关键词 超声 血流向量成像 能量损耗 涡流 Ultrasound Blood flow vector imaging Energy loss Vortex
  • 相关文献

参考文献7

二级参考文献74

  • 1Tanaka M,Sakamoto T,Sugawara S,et al.Blood flow structure and dynamics,and ejection mechanism in the left ventricle:analysis using echo-dynamography.J Cardiol,2008,52:86-101.
  • 2王新房.超声心动图.第4版.北京:人民卫生出版社,2009:228-238.
  • 3Wong KL,Kelso RM,Worthley SG,et al.Cardiac flow analysis applied to phase contrast magnetic resonance imaging of the heart.Ann Biomed Eng,2009,37:1495-1515.
  • 4Sengupta PP,Burke R,Khandheria BK,et al.Following the flow in chamber.Heart Fail Clin,2008,4:325-332.
  • 5Kim WY,Walker PG,Pedersen EM,et al.Left ventricular blood flow patterns in normal subjects:a quantitative analysis by threedimensional magnetic resonance velocity mapping.J Am Coll Cardiol,1995,26:224-238.
  • 6Walker PG,Cranney GB,Grimes RY,et al.Three-dimensional reconstruction of the flow in a human left heart by using magnetic resonance phase velocity encoding.Ann Biomed Eng,1996,24:139-147.
  • 7Pauschinger M,Knopf D,Pet Schauer S,et al.Dilated cardiomyopathy is associated with significiant changes in collagen type Ⅰ/Ⅲ ratio.Circulation,1999,99:2750-2756.
  • 8Kilner PJ, Yang GZ, Wilkes AJ, et al. Asymmetric redirection offlow through the heart. Nature, 2000,404(6779) : 759-761.
  • 9Hong GR, Kim M, Pedrizzetti G, et al. Current clinical applica-tion of intracardiac flow analysis using echocardiography. J Card-iovasc Ultrasound, 2013,21(4): 155-162.
  • 10Itatani K. When the blood flow becomes bright. Eur Heart J.2014,35(12):747-752.

共引文献37

同被引文献8

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部