摘要 阴极保护是保障油气管道安全运行的可靠技术。国际上普遍应用断电电位评价管道阴极保护状态。介绍了国内管道断电电位测量技术现状,存在的问题是断电电位测量延迟时间存在差异,不能获得准确的管-地极化电位。以新发布的美国腐蚀工程师协会标准NACE TM0497-2012为例,阐述了国际上普遍公认的阴极保护电位标准测试方法,包括测试断电电位的断电时间、电压冲击峰持续时间、参比电极精度和参比电极放置方法等。最后,提出了借鉴NACE TM0497-2012技术先进性,修订国家标准GB/T 21246-2007的建议。 The cathodic protection was the reliable technique for guarantee oil & gas pipeline safe operation. OFF-Potential was commonly used to evaluate the effectiveness of pipeline cathodic protection.The paper introduced the situation of domestic pipeline OFF-Potential testing technology, the problem was that there are differences in the delay time of the OFF-Potential testing, and can not get the pipeline-soil polarization potential. With the example of the new edition NACE TM 0497-2012, the paper expounded the internationally recognized standard testing method for cathodic protection potential, including powershutdown time, and voltage strike duration, and relative electrode precision, and relative electrode settlement.Finally, the suggestion of referring the advancement of NACE TM 0497-2012 and revising GB/T 21246-2007 were made.
作者 李杰 杨雪 王志斌 王燕 马伟平 LI Jie;YANG Xue;WANG Zhi-bin;WANG Yan;MA Wei-ping(CNPC South East Asia Pipeline Company Limited., Beijing 100028, China;Engineering and Technological Research Institute of PetroChina Tuha Oilfield, Shanshan 838202, China;PetroChina Fuel Oil Co., Ltd. Ningbo Daxie warehousing Branch, Ningbo 315812, China;PetroChina Pipeline R&D Center, Langfang 065000, China)
出处 《全面腐蚀控制》 2016年第12期3-5,79,共4页 Total Corrosion Control
关键词 阴极保护 通电电位 断电电位 测试方法 电压冲击峰 cathodic protection on-potential off-potential testing method voltage spike
  • 相关文献

参考文献7

二级参考文献29

共引文献80

同被引文献31

引证文献3

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部