期刊文献+

神经外科围手术期不同血红蛋白检测方式的比较及意义 被引量:1

Comparison and significance of different hemoglobin detection methods in the department of neurosurgery during perioperative period
下载PDF
导出
摘要 目的:探讨神经外科围手术期不同血红蛋白检测方式的差异以及意义。方法:收治进行择期脑膜瘤切除术的患者72例,选取术前进行麻醉诱导,选取合适的患者体位后、术中患者脉搏血氧血红蛋白变化达20%(SpHb)、输血前10 min、输血后0.5 h等4个时间节点进行血标本的抽取。对采集得到的血标本利用脉搏血氧测量仪法(SpHb)、血红蛋白专用测定仪(HCue)与碳氧血氧仪(tHb)进行比较,对几种方法的准确性、相关性以及一致性、时效性等进行评估。结果:对72例患者采用Sp Hb、HCue、tHb等方式进行测定,取得数据后分析发现,3者之间的相关关系较为明显。结论:HCue与tHb之间具有相关性和一定的一致性,但其测量值的准确性不如t Hb与HCue。 Objective:To investigate the difference and significance of different hemoglobin detection methods in the department of neurosurgery during perioperative period.Methods:72 patients underwent elective meningioma resection were selected.Anesthesia induction was performed before operation.The blood samples were taken at 4 time points after the patients' select theappropriate patient position,intraoperative pulse oximetry changes in patients up to 20%(SpHb),10 min before transfusion,and 0.5h after blood transfusion.The blood samples were collected and compared by pulse blood oxygen measuring instrument(SpHb),hemoglobin measurement instrument(HCue),carbon oxygen oximetry(tHb),and the accuracy,relevance,consistency,and timeliness of several methods were evaluated.Results:72 cases of patients using SpHb,HCue,tHb,and so on were measured,obtained data analysis found that,and the correlation between the 3 was more obvious.Conclusion:There is correlation and consistency between HCue and tHb,but the accuracy of the measurement is not as good as tHb and HCue.
作者 张纯伟 Zhang Chunwei(Department of Neurosurgery,the People's Hospital of Hanchuan City,Hubei Province 432300)
出处 《中国社区医师》 2016年第36期117-117,119,共2页 Chinese Community Doctors
关键词 神经外科 围手术期 血红蛋白 检测方式 Department of Neurosurgery Perioperative period Hemoglobin Detection method
  • 相关文献

参考文献6

二级参考文献85

  • 1宁婷.尿微量白蛋白检测的临床意义[J].实用医技杂志,2008,15(32):4596-4597. 被引量:3
  • 2程正江.血红蛋白和胆红素干扰临床化学分析的机理初探[J].国外医学(临床生物化学与检验学分册),2004,25(6):488-491. 被引量:27
  • 3王俊芳,王得新,高凤玲,徐忠宝.脑血管反应性检测方法的临床评价[J].中国现代神经疾病杂志,2006,6(6):459-462. 被引量:3
  • 4Lee JK, Kibler KK. Benni PB, et al. Cerebrovaseular reactivity measured by near-intrared spectroseopy. Stroke, 2009. 40:1820- 1826.
  • 5Aaslid R, Markwalder TM. Nornes H. Noninvasive transcranial Doppler ultrasound recording of flow velocity in basal cerebral arteries. J Neurosurg. 1982, 57:769-774.
  • 6Sharma D, Bithal PK, Dash HH, et al. Cerebral autoregulation and CO2 reactivity before and after elective supratentorial tumor resection. J Neurosurg Anesthesiol, 2010, 22:132-137.
  • 7Hoshi Y, Kobayashi N. Tamura M. Interpretation of near- infrared spectroscopy signals: a study with a newly developed perfused rat brain model. J Appl Physiol. 2001, 90:1657-1662.
  • 8Terborg C, Groschel K, Petrovitch A, et al. Noninvasive assessment of cerebral perfusion and oxygenation in acute ischemic stroke by near- infrared spectroscopy. Eur Neurol, 2009, 62:338-343.
  • 9Niioka T, Ohnuki S, Miyazaki Y. Individual differences in blood volume and oxygeenation in the brain during a cognitive task based on time-resolved spectroscopic measurements. Adv Exp Med Biol, 2010, 662:251-255.
  • 10Roche- Labarbe N. Carp SA. Surova A, et al. Noninvasive optical measures of CBV. StO(2), CBF index and rCMRO(2) in human premature neonates' brains in the first six weeks of life. Hm Brain Mapp. 2010. 31:341-352.