期刊文献+

Prediction of the effect on antihyperglycaemic action of sitagliptin by plasma active form glucagon-like peptide-1

Prediction of the effect on antihyperglycaemic action of sitagliptin by plasma active form glucagon-like peptide-1
下载PDF
导出
摘要 AIM: To investigate whether active glucagon-like peptide-1(GLP-1) is a prediction Factor of Effect of sitagliptin on patients with type 2 diabetes mellitus(GLP-1 FEST:UMIN000010645). METHODS: Seventy-six patients with type 2 diabetes, who had insufficient glycemic control [Hemoglobin A1c(Hb A1c) ≥ 7%] in spite of treatment with metformin and/or sulfonylurea, were included in the investigation. Patients were divided into three groups by tertiles of fasting plasma active GLP-1 level, before the administration of 50 mg sitagliptin. RESULTS: At baseline, body mass index, serum UA, insulin and HOMA-IR were higher in the high active GLP-1 group than in the other two groups. The high active GLP-1 group did not show any decline of Hb A1c(7.6% ± 1.4% to 7.5% ± 1.5%), whereas the middle and low groups indicated significant decline of Hb A1c(7.4 ± 0.7 to 6.8 ± 0.6 and 7.4 ± 1.2 to 6.9 ± 1.3, respectively) during six months. Only the low and middle groups showed a significant increment of active GLP-1, C-peptide level, a decreased log and proinsulin/insulin ratio after administration. In logistic analysis, the low or middle group is a significantexplanatory variable for an Hb A1 c decrease of ≥ 0.5%, and its odds ratio is 4.5(1.40-17.6)(P = 0.01) against the high active GLP-1 group. This remains independent when adjusted for Hb A1 c level before administration, patients' medical history, medications, insulin secretion and insulin resistance.CONCLUSION: Plasma fasting active GLP-1 is an independent predictive marker for the efficacy of dipeptidyl peptidase 4 inhibitor sitagliptin. AIM: To investigate whether active glucagon-like peptide-1(GLP-1) is a prediction Factor of Effect of sitagliptin on patients with type 2 diabetes mellitus(GLP-1 FEST:UMIN000010645). METHODS: Seventy-six patients with type 2 diabetes, who had insufficient glycemic control [Hemoglobin A1c(Hb A1c) ≥ 7%] in spite of treatment with metformin and/or sulfonylurea, were included in the investigation. Patients were divided into three groups by tertiles of fasting plasma active GLP-1 level, before the administration of 50 mg sitagliptin. RESULTS: At baseline, body mass index, serum UA, insulin and HOMA-IR were higher in the high active GLP-1 group than in the other two groups. The high active GLP-1 group did not show any decline of Hb A1c(7.6% ± 1.4% to 7.5% ± 1.5%), whereas the middle and low groups indicated significant decline of Hb A1c(7.4 ± 0.7 to 6.8 ± 0.6 and 7.4 ± 1.2 to 6.9 ± 1.3, respectively) during six months. Only the low and middle groups showed a significant increment of active GLP-1, C-peptide level, a decreased log and proinsulin/insulin ratio after administration. In logistic analysis, the low or middle group is a significantexplanatory variable for an Hb A1 c decrease of ≥ 0.5%, and its odds ratio is 4.5(1.40-17.6)(P = 0.01) against the high active GLP-1 group. This remains independent when adjusted for Hb A1 c level before administration, patients' medical history, medications, insulin secretion and insulin resistance.CONCLUSION: Plasma fasting active GLP-1 is an independent predictive marker for the efficacy of dipeptidyl peptidase 4 inhibitor sitagliptin.
出处 《World Journal of Diabetes》 SCIE CAS 2016年第11期230-238,共9页 世界糖尿病杂志(英文版)(电子版)
关键词 Dipeptidyl peptidase-4 inhibitor ACTIVE FORM glucagon-like peptide-1 Hemoglobin A1C Regression analysis Dipeptidyl peptidase-4 inhibitor Active form glucagon-like peptide-1 Hemoglobin A1c Regression analysis
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部