利用PT-8000型光度计建立了一种评价硫酸钡阻垢剂的新方法。通过与滴定法测试结果对比,两者能够获得一致的准确度,并且分析了阻垢剂浓度、酸碱环境和温度对于检测结果的影响。
A new evaluation method for barium sulfate scale inhibitor was established by PT-8000photometer.The testing results of the method and titration test were compared.It indicates that the methods are equal in accuracy.The influence of concentration of scale inhibitor,acid-base environment and temperature on the test results are observed as well.