期刊文献+

油田水质化验中应用苏林分类时SO_4^(2-)测定方法的选择 被引量:7

Measurement method selection for SO_4^(2-) determination in oilfield water test with Surin classification
下载PDF
导出
摘要 延长组油田水和地表水因为其矿化度水型的差异,苏林分类时对SO_4^(2-)测定结果的准确度要求也不同。根据《油田水分析方法SY/T5523—2006》推荐的SO_4^(2-)3种测定方法和已废止但仍在使用的EDTA络合滴定法,从经济因素、检测限和检测需求等方面进行了讨论,认为在进行苏林分类时SO_4^(2-)测定方法优先考虑浊度计法。 The different salinity water type in oilfield water and surface water has caused different requirements of accuracy in determining SO42– with Surin classification.This article describes three measuring methods of SO42-according to Oilfield Water Analysis Method Of SY/T5523-2006SO42-and EDTA complexometric titration that has been abolished but still in use with respect to economic factors,detection limit,and testing requirements.It concludes that turbidity meter method is preferred in Surin classified SO42-determination.
作者 郝健 黄天坤 王军 王奇 张虎 徐江峰 Hao Jian;Huang Tiankun;Wang Jun;Wang Qi;Zhang Hu;Xu Jiangfeng(Yanchang Oilfield, Yan’an 716000, China)
出处 《石化技术》 CAS 2017年第3期67-67,119,共2页 Petrochemical Industry Technology
关键词 SO42- 苏林分类 延长组 油田水 EDTA络合滴定法 SO42– Surin classification Yanchang Formation oilfield water EDTA complexometric titration