摘要 The readout electronics for a prototype soft X-ray spectrometer based on silicon drift detector(SDD),for precisely measuring the energy and arrival time of X-ray photons is presented in this paper.The system mainly consists of two parts,i.e.,an analog electronics section(including a pre-amplifier,a signal shaper and filter,a constant fraction timing circuit,and a peak hold circuit)and a digital electronics section(including an ADC and a TDC).Test results with X-ray sources show that an energy dynamic range of 1-10 keV with an integral nonlinearity of less than 0.1%can be achieved,and the energy resolution is better than 160 eV @ 5.9 keV FWHM.Using a waveform generator,test results also indicate that time resolution of the electronics system is about 3.7 ns,which is much less than the transit time spread of SDD(<100 ns)and satisfies the requirements of future applications. The readout electronics for a prototype soft X-ray spectrometer based on silicon drift detector (SDD), for precisely measuring the energy and arrival time of X-ray photons is presented in this paper. The system mainly consists of two parts, i.e., an analog electronics section (including a pre-amplifier, a signal shaper and filter, a constant fraction timing circuit, and a peak hold circuit) and a digital electronics section (including an ADC and a TDC). Test results with X-ray sources show that an energy dynamic range of 1-10 keV with an integral nonlinearity of less than 0.1% can be achieved, and the energy resolution is better than 160 eV @ 5.9 keV FWHM. Using a waveform generator, test results also indicate that time resolution of the electronics system is about 3.7 ns, which is much less than the transit time spread of SDD (<100 ns) and satisfies the requirements of future applications.
出处 《Nuclear Science and Techniques》 SCIE CAS CSCD 2017年第1期94-99,共6页 核技术(英文)
基金 supported by the National Natural Science Foundation of China(Grant No.11205154)
关键词 Energy and time measurement SOFT X-ray detection Silicon DRIFT DETECTOR READOUT ELECTRONICS Energy and time measurement Soft X-ray detection Silicon drift detector Readout electronics
  • 相关文献

参考文献3

二级参考文献75

  • 1Acam messelectronic GMBH.Solution in time datasheet,2007.Available:http://www.acam.de/products/ time-to-digital-converters/tdc-gpx/.
  • 2Szplet R,Kalisz J,Szymanowski R.IEEE Trans Instrum Meas,2000,49:879-883.
  • 3Kalisz J,Szplet R,Pasierbinski J.IEEE Trans Instrum Meas,1997,46:851-856.
  • 4Wu J,Shi Z,Wang I Y.Proc IEEE Conf Rec NSS,2003,1:177-181.
  • 5Song J,An Q,Liu S.IEEE Trans Nucl Sci,2006,53:236 -241.
  • 6Liu S,Guo J,Zhang Y.Nucl Tech,2006,29:72-76.
  • 7Altera Corporation.Cyclone Device Handbook,2007.Available:http://www.altera.com/products/devices/cyclone/cyc-index.jsp.
  • 8Kalisz J,Paw?owski M,Pe?ka R.J Phys E:Sci Instrum,1985,18:444-452.
  • 9Aveynier J,Van Zurk R.Nucl Instrum Meth,1970,78:161-170.
  • 10Otsuji T.IEEE J Solid State Circuits,1993,28:941-947.

共引文献9

同被引文献2

引证文献3

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部