现代住宅非承重墙一般采用蒸压加气混凝土砌块填充,然后在一侧施工保温材料,连接部分用黏结砂浆。这种施工过程工序多,界面间会存在很多热桥,降低了工程应用的热工效率。探讨一种蒸压加气混凝土(AAC)和聚苯乙烯泡沫挤塑聚苯板(XPS)复合砌块的性能,旨在找到一种简化施工过程和减少墙体热桥的方法,进而提高复合砌块施工效率和功能效率。
This paper explores the performance of composite block made from autoclaved aerated concrete(AAC)and polystyrene foam extruded polystyrene(XPS),try to find a way to simplify the construction process and reduce the wall thermal bridge in order to improve the construction efficiency and functional efficiency of composite block.