摘要 在信息化技术快速发展的今天,机房的安全性问题已变得极为突出;高效监控并管理机房内的各种信息,是保障机房内设备安全性的必然手段。本文针对将各种监控信息集中出现在同一平台上的实际需求,提出并实现了机房环境下的集中式监控系统,并首次将"PRISM"技术原则引入到监控系统平台的设计中,以满足用户对监控平台的技术要求。该系统平台除了监控并管理UPS、精密空调、温湿度信息之外,还监控并管理着漏水、烟雾、蓄电池、机柜、市电、消防及视频等多种信息。本集中式智能监控系统具有诸多技术优势,如统一的软硬件及配件平台、真正一体化设计、全开放模式、优异的"防误报警"智能逻辑技术等。 I n the current circumstance,the development of information technology is so fast,the security problem of computer roomhas become very prominent;the effective monitoring and managing all kinds of information in the computer room,is the necessary means toguarantee the safety of equipment in the computer room.Aiming at the need that all kinds of information will appear on the same platform,this paper provides and realizes the centralized monitoring system in computer room environment,and in order to satisfy the requirements ofthe user for the monitor platform,this paper introduces the"PRISM"technology principle to the design of the monitoring system platform forthe first time.Besides the information of UPS,precision air-condition,temperature and humidity,this platform can also monitor and managethe information of leaking water,smoke,storage battery,cabinets,electric supply,fire control,video and other information.This centralizedintelligent monitoring system has many advantages,such as unified platform for the software,hardware and accessories,real integration design,full open mode,excellent"anti-misinformation"intelligent logic technology,etc.
作者 李华松 张进铎 马迅飞 张俊 侯天雄 李华松;ZHANG Jin-duo;MA Xun-fei;ZHANG Jun;HOU Tian-xiong
出处 《信息技术与信息化》 2017年第5期43-47,共5页 Information Technology and Informatization
关键词 集中式监控 机房 “PRISM”原则 UPS 精密空调 温湿度 Centralized monitoring Computer room “PRISM” principle UPS Precision air-condition Temperature and humidity
  • 相关文献

参考文献6

二级参考文献18

共引文献17

同被引文献60

引证文献8

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部