摘要
目的探讨医用悬浮床的质控检测项目及其标准并根据测试结果反映我院在用悬浮床的性能现状,提高其使用的安全性和准确性。方法采用专业的检测设备对悬浮床的温度、接触压力、颗粒污染、电气安全等项目进行检测。结合检测过程中发现的问题,归纳产生问题的原因以及处理方法。结果得出了各检测项目的合格率,总结出了涉及悬浮床检测不合格的相关因素。结论提出了预防性保养医用悬浮床的方法以及使用过程中的注意事项和改进措施,从而在一定程度上提高了医疗质量,保障了医疗安全。
Objective This paper aimed to discuss the quality control testing items and standards ofmedical suspension bed,and reflected the performance status of suspended bed in use based on the testresults to improve the safety and accuracy.Methods The temperature,contact pressure,particle pollution,electrical safety and other items of the suspension bed were tested by the professional testing equipment.Combined with the problems found in the detection process,the causes and treatment of problems weresummarized.Results The qualified rate of each item was obtained,and the related failure factors of thesuspension bed were summarized.Conclusion The paper put forward preventive maintenance measures,as well as attention and improvement method during use,which improved the quality of medical care andensured the safety to a certain extent.
作者
张明旭
ZHANG Ming-xu(Department of Medical Eqiupment, the174 Hospital of PLA, Xiamen Fujian361003, China)
出处
《中国医疗设备》
2017年第7期38-40,93,共4页
China Medical Devices
关键词
医用悬浮床
质量控制
风险管理
传感器
medical suspension bed
quality control
risk management
sensor