摘要
通过实验找到循环水总磷含量的最佳范围,并在现场进行应用性试验来优化总磷控制指标,可最大程度的发挥水处理的有效性,避免浪费、降低成本,同时减少水体污染。
Through experimenting to find the optimal range of total phosphorus content of circulating water,and applying test in the field,the total phosphorus control index was optimized in Circulating water syste.These can maximize the effectiveness of water treatment chemicals,to avoid waste,to reduce costs,and to reduce water pollution.
作者
彭卫
罗旭
杜天悦
PENG Wei;LUO Xu;DU Tian-yue(Urumqi Petrochemical Company Research Institute of China National Petroleum, Urumqi 830019, China)
出处
《全面腐蚀控制》
2017年第7期15-17,共3页
Total Corrosion Control
关键词
循环水系统
总磷指标
缓蚀性能
阻垢性能
circulating water system
total phosphorus indicator
inhibition corrosion performance
prevent fouling performance