摘要
本文对EDTA滴定法测定工业循环水中锌离子测定的方法研究,对EDTA浓度、取样体积、样品pH值的调节、加热温度等样品处理方法和处理条件进行试验,减少检测误差,提高分析的准确度。
Industrial circulating water in this paper,the EDTA titration method for the determination of zinc ions,the concentration of EDTA,sampling,sample volume of pH adjustment,heating temperature,sample processing methods and processing conditions,such as reduce the detection error,improve the accuracy of analysis.
作者
李红
郭景玉
LI Hong;GUO Jing-yu(Research Institute of Urumqi Petrochemical Company, PetroChina, Urumqi 830019, China)
出处
《全面腐蚀控制》
2017年第7期23-25,共3页
Total Corrosion Control