通过分析国网重庆市电力公司武隆县供电分公司低压台区线损精细化管理现状,总结了造成台区线损统计异常的主要因素,并提出相应的整改对策,以期为其他供电公司提供参考。
Based on the analysis of the current situation of the delicacy management of the line loss of the low-voltagetransformer area in Wulong Power Supply Branch of State Grid Chongqing Electric Power Company,this paper summarizesthe main factors causing abnormal line loss statistics of the transformer area as well as presenting relevantmeasures of improvement to provide reference for other power supply companies,
作者
罗佳欣
杜勇
熊孔明
LUO Jiaxin;DU Yong;XIONG Kongming(Wulong Power Supply Branch of State Grid Chongqing Electric Power Company, Chongqing 408500, P. R. China)
出处
《重庆电力高等专科学校学报》
2017年第1期36-37,58,共3页
Journal of Chongqing Electric Power College
关键词
低压台区
线损
管理
low-transformer area
line loss
management