期刊文献+

水下应用的电容式微机械超声换能器阵列设计 被引量:1

Array design and test of capacitive micromachined ultrasonic transducer used underwater
下载PDF
导出
摘要 为提高用于水下成像的电容式微机械超声换能器的指向性,文中用ANSYS力电耦合分析法设计了工作频率为400 k Hz的收发一体传感器的结构参数并完成了实验验证。同时研究了阵列设计方法,分析了电容式微机械超声换能器阵列各参数对指向性的影响,完成了从微小敏感单元到阵列的设计,实现了阵列指向性的优化设计。该阵列为16阵元的线阵,阵元间距为1.925 mm,阵元宽度为1.82 mm。进行了水下指向性测试,实验表明该线阵的-3 dB主瓣宽度为5?,最大旁瓣级为-13.5 dB,对称性好。该设计是实现较远距离的探测,提高成像分辨率的前提。 In order to improve the directivity of capacitive micromachined ultrasonic transducer used inunderwater imaging,the structure parameters of a transceiver integrated sensor are designed using force electriccoupling analysis method in this paper,the working frequency of which is400kHz and experimental verificationis completed.The array design criterion is studied,the influence of various parameters of CMUT array on thedirectivity is analyzed,the design from cell to array is completed,and the optimum design of array directivityis realized.A linear array is designed,which has16elements,element distance is1.925mm,and element widthis1.82mm.Underwater directivity test is conducted,the experiments show that the3dB main lobe widthof the line array is5°,maximum sidelobe level is??13.5dB,and it has good symmetry.The studies lay afoundation for long distance detection and high resolution imaging.
作者 郝聪聪 何常德 梁伟健 何昱蓉 HAO Congcong;HE Changde;LIANG Weijian;HE Yurong(Key Laboratory of Instrumentation Science & Dynamic Measurement, Ministry of Education, North University of China,Taiyuan 030051, China)
出处 《应用声学》 CSCD 北大核心 2017年第5期382-388,共7页 Journal of Applied Acoustics
基金 国家杰出青年科学基金项目(61525107) 国家重点研发项目(2016YFC0101900)
关键词 电容式微机械超声换能器 阵列设计 ANSYS 指向性 Capacitive micromachined ultrasonic transducer Array design ANSYS Directivity
  • 相关文献

参考文献3

二级参考文献52

  • 1郝震宏,汤亮,乔东海,汪承灏.硅微压电超声换能器的设计与制作[J].传感技术学报,2006,19(05B):2272-2275. 被引量:2
  • 2杜功焕.声学基础[M].北京:北京科学技术出版社,1986..
  • 3MO J H, ROBINSON A L, FITTING D W, et al. Micromachining for improvement of integrated ultrasound transducer sensitivity[J]. IEEE Transactions on Electron Devices, 1990, 37( 1 ): 134-140.
  • 4MO J H, FOWLKES J B, ROBINSON A L, et al. Crosstalk reduction with a micromachined diaphragm structure for integrated ultrasound transducer arrays[J]. IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control, 39(1), 1992: 48-53.
  • 5BEMSTEIN J J, FINBERG S L, HOUSTON K, et al. Micromachined high frequency ferroelectric sonar transducers[J]. IEEE Transactions on Ultrasonics Ferroelectrics and FrequencyControl, 1997,44(5):960-969.
  • 6MOHAMED H, POLLA D, EBB1NI E, et al. Micromachined piezoelectric ultrasonic imaging transducer[C]. Microelectro- mechanical Systems Conference, 2001:95-98.
  • 7PERCIN G, BUTRUS T, YAKUB K. Piezoelectrically actuated flextensional micromachined ultrasound transducers--I:theory[J]. IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control, 2002,49 (5): 573-584.
  • 8BABOROWSKI J, MURALT P, LEDERMANN N, et al. PZT coated membrane structures for micromachined ultrasonic transducers[C]. Proceedings of the 13th IEEE International Symposium, 2002: 483-486.
  • 9MURALT P, LEDERMANN N, BABOROSKI J, et al. Piezoelectric micromachined ultrasonic transducers based on PZT thin films[J]. IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control, 2005,52 (12):2276-2288.
  • 10MESCHER M J, HOUSTON K, BERNSTEIN J J, et al. Novel MEMS microshell transducer arrays for high-resolution under water acoustic imaging applications[C]. Sensors, Proceedings of IEEE, 2002, 1: 541-546.

共引文献41

同被引文献3

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部