期刊文献+

国外进口废热锅炉修复技术研究

Research on repair technique of imported waste heat boiler
下载PDF
导出
摘要 某丁辛醇装置的废热锅炉是从德国进口的设备,该设备在现场运行过程中在发现有泄漏,经技术分析发现在内部急冷盘管上有泄漏点。将设备整体拆卸后查找设备泄露原因,制定修复方案,进行修复。修复后的设备达到了原生产工艺要求。 The waste heat boiler of a2-ethyl hexanol plant was imported from Germany.It was found that this equipment had leakage during on-site operation.Through technical analysis,it was found that there were leaking points on the internal quenching coils.The equipment was entirely disassembled and repaired to find the causes for leakage and make repair plan.After repair,application reached original production process requirement.
作者 任召春 Ren Zhaochun(Machinery Factory of PetroChina Daqing Petrochemical Company,Daqing 163714,China)
出处 《炼油与化工》 2017年第5期46-48,共3页 Refining And Chemical Industry
关键词 废热锅炉 螺旋盘管 盘管套筒 修复技术 waste heat boiler spiral coil coil sleeve repair technique