不同机型PET-CT中CT采集条件与受检者有效剂量关系的研究 被引量:4

Research on the relationship between acquisition conditions of CT and effective dose for subject in different models of PET-CT
下载PDF
导出
摘要 目的:研究不同机型PET-CT中CT采集条件与受检者有效剂量的关系,为确定适合不同机型的临床最优化采集方案提供参考依据。方法:实验使用GE Discovery ST-16和Discovery Elite两种机型的PET-CT,CT部分所致剂量使用仿真人体模型(Model RS-550)实验获得。CT采集条件:(1)自动管电流30~250 mA,噪声指数(NI)值8~30,间隔2,其他采用中国医学科学院肿瘤医院临床实际采集条件,即管电压120 kV,螺距(Pitch):Discovery ST-16型为1.75,Discovery Elite型为0.984,转速:Discovery ST-16型为0.8 s,Discovery Elite型为0.5 s;(2)自动管电流低限均为30 mA,高限为210~350 mA,间隔为20 mA,NI值为14,其他临床实际采集条件同上;(3)Pitch:Discovery ST-16型分别为1.75、1.375和0.938,Discovery Elite分别为1.375和0.984,管电压120 kV,自动管电流为30~250 mA,NI值为14,转速:Discovery ST-16型为0.8 s,Discovery Elite型为0.5 s;(4)两机型转速均分别为0.5 s、0.8 s和1.0 s,管电压120kV,自动管电流为30~250 mA,NI值14,Pitch:Discovery ST-16型为1.75,Discovery Elite型为0.984。模拟临床PET-CT分段扫描方式使用上述条件分别对仿真人体模型RS-550进行扫描,记录各种条件下剂量长度乘积(DLP),并计算有效剂量(ED_(CT))。结果:①对固定的自动管电流、Pitch及转速,两机型CT部分所致有效剂量随NI值增加而降低,且Discovery ST-16型降低幅度大于Discovery Elite型;②对固定的NI值、Pitch及转速,两机型的ED_(CT)随自动管电流的增加线性增加,Discovery ST-16型增加幅度大于Discovery Elite型;③对固定的自动管电流、NI值及转速,ED_(CT)随Pitch的增加而降低;④对固定的管电流、NI值及Pitch,有效剂量随转速的增加而增加;⑤不同扫描条件下,两机型总有效剂量在4.93~24.00 mSv范围内;⑥在临床扫描条件下,Discovery Elite型受检者ED_(CT)均低于Discovery ST-16型。结论:不同型号的PETCT,在临床使用中多采用不同CT扫描条件,而扫描所致辐射剂量也因此有较大变化。在临床应用中,应结合临床需求选择适用于不同机型的最佳采集方案。 Objective:To study on the relationship between collecting conditions of CT and effective dose for subject indifferent models of PET-CT in order to provide a reference for the determination of the optimal collecting scheme that could suitdifferent models of PET-CT.Methods:Two models of PET-CT which included GE Discovery ST-16PET-CT and GE DiscoveryElite were adopted as experiment equipment,and the agent dosage of CT part obtained from simulation experiment ofanthropomorphic phantom(Model RS-550).Collecting conditions of CT included:(1)auto-tube current was30-250mA,noiseindex(NI)was8-30,the interval was2,and the other conditions used actually clinical collecting conditions:tube voltage was120kV,and pitches respectively were1.75for ST-16and0.984for Elite,and rotation speeds respectively were0.8s for ST-16and0.5s for Elite.(2)both of low limits of auto tube current of the two models of PET-CT were30mA,and range of high limit wasfrom210to350mA,and the interval was20mA,and NI was14,and the other conditions were the same with above those in(1).(3)Pitch:ST-16respectively chose1.75,1.375and0.938,and Elite respectively chose1.375and0.984,and tube voltage was120kV,and auto tube current was30-250mA,and NI was14,and rotation speed of ST-16and Elite were respectively were0.8sand0.5s.(4)rotation speed of two models of PET-CT respectively chose0.5s,0.8s and1.0s,and tube voltage chose120kV,andauto tube current chose30-250mA,and NI was14,and pitches of ST-16and Elite respectively were1.75and0.984.The aboveconditions were respectively was applied to scan anthropomorphic phantom(Model RS-550)through simulated step-scanmethod of clinical PET-CT,and then the dose-length product(DLP)under different conditions were recorded and the effectivedose(EDCT)was calculated.Result:1)When the automatic tube current,Pitch and rotation speed were unchanged,the effectivedoses caused by CT part of the both of two models of PET-CTs were decreased with the increasing of NI,and the decreasingamplitude of ST-16was larger than that of Elite.2)When the NI,Pitch and rotation speed were unchanged,the EDct of the twomodels of PET-CTs was increased with the increasing of automatic tube current,and the increasing amplitude of ST-16waslarger than that of Elite.3)When the automatic tube current,NI and rotation speed were unchanged,the EDct of the two modelsof PET-CTs was decreased with the increasing of Pitch.4)When the automatic tube current,NI and Pitch were unchanged,theeffective dose was increased with the increasing of rotation speed.5)Under different scanning condition,the totally effectivedose of the two models of PET-CTs was in the range of4.93mSv and24.00mSv.6)Under the clinical scanning condition,theeffective dose of all of the patients who received Elite were lower than that of ST-16.Conclusion:Different model of PET-CTcommonly chooses different scanning condition in clinical application,therefore,the radiation dose of scanning in differentcondition exists obviously difference.In clinical application,the scanning condition should choose the optimal collectingscheme of different model by combining with the clinical requirement.
作者 吴一田 耿建华 杜召猛 毕高畅 齐雍鹤 张朝坤 郑容 吴宁 WU Yi-tian;GENG Jian-hua;DU Zhao-meng(Department of PET-CT Center and Nuclear Medicine, National Cancer Center/Cancer Hospital,Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021,China)
出处 《中国医学装备》 2017年第10期13-18,共6页 China Medical Equipment
基金 国际科技合作项目(2009DFA32960)"PET-CT脑分子影像研究与应用平台及针灸中枢机理探索" 中国癌症基金会北京希望马拉松专项基金(LC2013A13和LC2016A02)"PET-CT的辐射剂量和图像质量的模型研究"和"PET-CT及SPECT SPECT-CT受检者辐射剂量的研究"
关键词 正电子发射断层扫描 体层摄影术 自动管电流 有效剂量 CT Positron emission tomography Body section radiography Automatic tube current Effective dose CT
  • 相关文献

参考文献10

二级参考文献129

共引文献99

同被引文献41

引证文献4

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部