期刊文献+

Comparison of CIM~ C4-HLD monolithic column with Sartobind phenyl membrane column for pIDKE2 purification

Comparison of CIM~ C4-HLD monolithic column with Sartobind phenyl membrane column for pIDKE2 purification
下载PDF
导出
摘要 The main component of the Center for Genetic Engineering and Biotechnology(CIGB)candidate vaccine against Hepatitis C virus(HCV)is the pIDKE2 plasmid.The current designed downstream process for the production of pIDKE2 fulfils all regulatory requirements and renders the required quantities of pharmaceuticalgrade plasmid DNA(pDNA)with 95%purity.The advantages of this procedure include high plasmid purity and the elimination of undesirable additives,such as toxic organic extractants and animal-derived enzymes.However,yields and consequently the productivity of the process are low.Previous work demonstrated that the most critical step of the process is the reverse phase chromatography,where conventional porous particle resins are used.Therefore,to increase the process productivity,alternative technologies such as membranes and chromatographic monoliths were tested as alternative options for this critical step.Here,a comparison between the behaviors of CIM~ C4-HLD and Sartobind phenyl matrices was performed.To obtain higher productivities and purities,the dynamic binding capacities and selectivities were evaluated.The results showed that both matrices had a similar capacity for pIDKE2 plasmid,but the separation of pDNA isoforms using CIM~ technology was much better than that with Sartobind.Additionally,the optimal conditions for loading plasmid DNA on a CIMC4-HLD 800-mL monolithic column in a real production process were determined.These optimizations will allow production levels to satisfy the high plasmid consumption demanded by clinical trials. The main component of the Center for Genetic Engineering and Biotechnology(CIGB)candidate vaccine against Hepatitis C virus(HCV)is the pIDKE2 plasmid.The current designed downstream process for the production of pIDKE2 fulfils all regulatory requirements and renders the required quantities of pharmaceuticalgrade plasmid DNA(pDNA)with 95%purity.The advantages of this procedure include high plasmid purity and the elimination of undesirable additives,such as toxic organic extractants and animal-derived enzymes.However,yields and consequently the productivity of the process are low.Previous work demonstrated that the most critical step of the process is the reverse phase chromatography,where conventional porous particle resins are used.Therefore,to increase the process productivity,alternative technologies such as membranes and chromatographic monoliths were tested as alternative options for this critical step.Here,a comparison between the behaviors of CIM~ C4-HLD and Sartobind phenyl matrices was performed.To obtain higher productivities and purities,the dynamic binding capacities and selectivities were evaluated.The results showed that both matrices had a similar capacity for pIDKE2 plasmid,but the separation of pDNA isoforms using CIM~ technology was much better than that with Sartobind.Additionally,the optimal conditions for loading plasmid DNA on a CIMC4-HLD 800-mL monolithic column in a real production process were determined.These optimizations will allow production levels to satisfy the high plasmid consumption demanded by clinical trials.
出处 《色谱》 CAS CSCD 北大核心 2017年第10期1028-1036,共9页 Chinese Journal of Chromatography
基金 Center for Genetic Engineering and Biotechnology and BIA Separations Fund
关键词 MEMBRANE MONOLITH downstream processing PLASMID DNA (pDNA) BREAKTHROUGH supercoiled (SC) PLASMID open circular (OC) PLASMID membrane monolith downstream processing plasmid DNA(pDNA) breakthrough supercoiled(SC)plasmid open circular(OC)plasmid
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部