摘要
介绍了70m^3聚合釜增加釜顶冷凝器的技术改进,通过增加釜顶冷凝器及相应自控化程序改造,将70m3聚合釜产能由2.5万吨/年提升至3万吨/年。对比分析了采用釜顶冷凝器前后的工艺运行及产品质量情况。
the article introduces the70m3polymerization kettle increase still top condenser technology improvement,by increasing the kettle top condenser and the corresponding control change program transformation,will be70m3polymerization kettle capacity by25000tons/year up to30000tons/year.Compared with that of kettle top condenser before and after the process and product quality.
作者
张睿
张喜伟
ZHANG Rui(xinjiang huatai ChongHuaGong co., LTD., xinjiang urumqi 830019)
出处
《化工管理》
2017年第15期188-190,共3页
Chemical Engineering Management
关键词
PVC
70m3聚合釜
釜顶冷凝器
应用
PVC 70 m3 polymerization kettle still top condenser application