摘要 冷却塔的冷却能力是衡量其性能的重要参数,多数测试标准对冷却能力的评价方法可分为冷却水量法与冷却水温法。本文通过一组实测数据对比分析了冷却水量法与冷却水温法这两种评价方法以及各标准间的差异性及存在问题,得出国内测试标准的冷却水温法评价结果比冷却水量法和美国CTI标准评价结果均偏差约2.3%的结论。并分析出主要原因是标准中设计水温差计算时风量取值为实测风量,为以后标准的修订提供了技术支持。 The cooling ability is one of important parameters to measure the capacity of the cooling tower.Generally speaking,the current cooling ability evaluation method consists of the cooling water yield method and the cooling water temperature method.The study made a comparative analysis of the two kinds of cooling evaluation methods though a group of testing data as well as the distinctions and limitations between the different standards.The result made a conclusion that there exists a2.3%deviation of the evaluation result between the domestic cooling water yield method and the cooling water temperature method as well as the American CTI evaluation standard.In addition,the causation of the results was also analyzed,which mainly owns to the air volume which is calculated as the measured air volume during the design of water temperature difference calculation of the standard,which provides the technical support for the further standard modification.
作者 马麟 赵顺安 章立新 MA Lin;ZHAO Shunan;ZHANG Lixin(University of Shanghai for Science and Technology,School of Energy and Power Engineering,Shanghai 200093,China;Department of Hydraulics,China Institute of Water Resources and Hydropower Research,Beijing 100038,China)
出处 《中国水利水电科学研究院学报》 北大核心 2017年第3期213-217,共5页 Journal of China Institute of Water Resources and Hydropower Research
关键词 冷却塔 热力性能评价方法 对比分析 差异性 cooling tower cooling ability evaluation method Comparative analysis the distinctions
  • 相关文献

参考文献2

二级参考文献19

共引文献3

同被引文献44

引证文献5

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部