摘要 炉水循环泵是电厂锅炉最主要的设备,炉水循环泵电机腔室温度升高也是锅炉运行中面临的主要问题。通过对炉水循环泵的运行监视和实测数据的分析,认为炉水循环泵冷却器堵塞和腔室内积聚污物是问题的根本原因,并从运行及检修角度给出了合理的建议。 Boiler water circulating pump is the most important equipment of power plant boilers,temperature rising of motor chamber in the boiler water circulating pump is also the main problem in boiler's operation.Through the operation monitoring and measurement data analysis of the boiler water circulating pump,it is considered that the blockage of the boiler water circulating pump cooler and the accumulation of dirt in the chamber are the root causes of the problem,and the reasonable suggestions are given from the perspective of operation and maintenance.
作者 李忠石 LI Zhongshi(Shenhua Guoneng Shaanxi Guyuan Fugu Energy Co.,Ltd,Fugu,Shaanxi,719407)
出处 《神华科技》 2017年第11期55-57,共3页 Shenhua Science and Technology
关键词 炉水循环泵 电机腔室 高压冷却水 低压冷却水 Boiler Water Circulating Pump Motor Chamber High-pressure Cooling Water Low-pressure Cooling Water