期刊文献+

连续重整装置进料换热器冷侧压降升高的原因分析 被引量:2

Cause analysis of cold side pressure drop rising of reformer feed heat exchanger in continuous catalytic reforming unit
下载PDF
导出
摘要 哈尔滨石化公司的连续重整装置重整进料换热器出现压降升高的现象,导致循环氢流量大幅度下降,使装置运行出现困难。文中结合装置的介质特性分析了出现该故障的原因,采取了相应的处理措施,收到理想的效果。 The pressure drop rising phenomenon occurred in the reformer feed heat exchanger of the continuous reforming unit,which caused the recycle hydrogen flow remarkably decreased and made the unit operation difficult.Combined with the characteristics of the medium of the unit,this paper analyzed the causes for the occurrence of this fault,adopted corresponding treatment measures,obtained ideal effect.
作者 齐铁忠 Qi Tiezhong(PetroChina Harbin Petrochemical Company, Harbin 150056, China)
出处 《炼油与化工》 2017年第6期40-42,共3页 Refining And Chemical Industry
关键词 连续重整 进料换热器 压降 结盐 结焦 continuous reforming feed heat exchanger pressure drop salt deposition coking